Analysis Of Testing On Circuit Breaker Bay 7AB3 Gistet Adipala In The Framework Of Biennial Maintenance
Main Article Content
Abstract
Power Breaker (PMT) is a switch that is used to connect or disconnect electrical power in normal conditions or in abnormal conditions or disturbances. To always maintain the reliability of the PMT, regular maintenance needs to be carried out. This writing aims to identify the working principles of the PMT bay 7AB3, what tests are carried out on the PMT and identify the reliability and suitability of the Power Breaker (PMT). In this writing analysis, data from Power Breaker Maintenance (PMT) results during the 2 (two) yearly maintenance period for 2022 are used and compared with the minimum standards set. The results of the analysis state that in testing the grounding resistance for the R, S, T phases is 0.5Ω; 0.4Ω; 0.7Ω and the difference in simultaneous resistance time for open time condition 1 is 0.9 ms, open time condition 2 is 0.65 ms and closing time condition is 2.15 ms. In the contact resistance test, the value for phase R was 39.1 µΩ; S phase of 36.7 µΩ; phase T is 20.7 µΩ where this value is in accordance with the permitted standard, namely.
Article Details
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Authors who publish with FIDELITY : Jurnal Teknik Elektro agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution-ShareAlike 4.0 International License (CC BY-SA 4.0) that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.
Jurnal FIDELITY : Jurnal Teknik Elektro is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Accepted 2024-01-06
Published 2024-01-31
References
A. Goeritno, B.I. Syaputra, (2014). ―Kelayakan Operasi Pemutus Tenaga (PMT) Berdasarkan Kualitas Gas, Keserempakan Titik Titik Kontak di JUTEKS (Jurnal Teknik Elektro dan Sains), Vol.1, No.1, hlm. 1-7. Aslimeri, dkk. 2008. Teknik Transmisi Tenaga Listrik. Jakarta Departemen Pendidikan Nasional Elvansyah, M.R. 2016. Pemutus rangkaian yang menggunakan gas SF6 sebagai sarana pemadam busur api. Banjarmasin:Politeknik Negeri Banjarmasin. Guntoro, H. 2013. Pemeliharaan PMT di Cikarang Listrindo. Jakarta : Universitas Mercu Buana.. MARTIN PANGSONGGO (2001) Peran Pemutus dan pemisah sebagai Peralatan Hubung (switchgear) pada Gardu Induk 150 kV, Institut Sains dan Teknologi AKPRIND, Yogyakarta Pranomo, I. 2019, Analisis Pengujian Pemutus Tenaga Bay Gondang 2 Dalam pemeliharaan 2 Tahunan Di Gardu Induk Palur. (Skripsi Yang Tidak Dipublikasikan, Universitas Muhammadiyah Surakarta.,2019) SKDIR 0520-2.K/DIR/2014, 2014, Buku Pedoman Pemeliharaan Pemutus Tenaga (PMT) No dokumen : PDM/PGI/07:2014, PT PLN (Persero), Jakarta. Indonesia SKDIR 114.K/DIR/2010, 2010, Himpunan Buku Petunjuk Batasan Operasi Dan Pemeliharaan Penyaluran Tenaga Listrik - Buku Pedoman Pemeliharaan Pemutus Tenaga No dokumen : 7-22/ HARLUR- PST/2009, PT PLN (Persero), Jakarta. Indonesia Buku petunjuk operasi pemeliharaan Pemutus Tegangan (PMT) B.1.1.2.10.3 A. Nugraha, F. Felycia, and A. Suryana, “Distribution Network System Reliability Index Study PLN North Banten in 2023”, Fidelity, vol. 5, no. 3, pp. 201-205, Sep. 2023.